J.H.JIN의 모든 글

TPi-TCSX

Glass Plate for Nikon Ti2/TS2R XY manual stage<TC-S-SR/SRF>
・10 year free-repair service for glass breakage ( Applied harden glass )
・With Plate LED Indicator
・Temp. setting range:Ambient – 60℃

Plate:TCSX

Tokai-Hit TPi-TCSX Themo Plate
Dimensions:W127.5×D85.5 mm
Heating area:W115×D75 mm
Glass thickness:0.5 mm
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

Nikon manual:Nikon Ti/Ts2R TC-S-SR

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter

TPi-108RX

Glass Plate for Nikon Ti2/Ti/TE2000 Rectangular stage with φ108mm opening
・10 year free-repair service for glass breakage ( Applied harden glass )
・With Plate LED Indicator
・Temp. setting range:Ambient – 60℃

Plate:108RX

Tokai-Hit TPi-110RX Mady Thermo Plate
Glass Plate for Olympus IX series Cross stage with φ110mm opening
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

Nikon manual:NikonTi TI-SR/SSR
Nikon motorized:Nikon Ti TI-S-E/TI-S-ER (※for round opening)

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter  

TPiD-VITX

ThermoPlate for Vitrification for stereo microscopes ( Universal type )
・10 year free-repair service for glass breakage ( Applied harden glass )
・With Plate LED Indicator
・Temp. setting range:Ambient – 60℃ *For thawing process of frozen embryo

Plate:VITX

Tokai-Hit TPiD-VITX Themo Plate
Dimensions:W230×D148 mm
Heating area:(Glass part):W95×D128 mm×2
Glass thickness:0.5 mm
Leg adjustable range:75~100 mm
Controller TPi

Controller:TPiD


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:100W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illumination bases for stereo microscopes
Nikon Illumination bases for stereo microscopes
Leica Illumination bases for stereo microscopes
ZEISS Illumination bases for stereo microscopes

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter

TPiD-SZX2DX

Entire Surface Heating Plate for Olympus SZX16/10
– SZX2-ILLB/ILLD/ILLK/ILLT/ILLTQ/ILLTS
・10 year free-repair service for glass breakage ( Applied harden glass )
・With Plate LED Indicator
・Temp. setting range:Ambient – 50℃

Plate:SZX2DX

Tokai-Hit TPiD-SZX2DX Themo Plate
Dimensions:W357×D243 mm
Heating area:(Glass part):W128×D95 mm
Glass thickness:0.5 mm
Controller TPi

Controller:TPiD


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:100W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illuminator base:SZX2-ILLB/ILLK/ILLD
EVIDENT Illuminator base:SZX2-ILLT/ILLTQ/ILLTS

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter 

TPi-WL

Glass Plate(Large type)
For stereo microscopes Illumination bases
・Temp. setting range:Ambient – 60℃

Plate:WL

Tokai-Hit TPi-WL Themo Plate
imensions: W310×D220 mm
Heating area: W250×D170 mm
Glass thickness: 1.5
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illumination bases for stereo microscopes
Nikon Illumination bases for stereo microscopes
Leica Illumination bases for stereo microscopes
ZEISS Illumination bases for stereo microscopes

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter 

TPi-W

Glass Plate(Large type)
For stereo microscopes Illumination bases
・Temp. setting range:Ambient – 60℃

Plate:W

Tokai-Hit TPi-W Themo Plate
Dimensions:W230×D180 mm
Heating area:W180×D140 mm
Glass thickness:1.5 mm
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illumination bases for stereo microscopes
Nikon Illumination bases for stereo microscopes
Leica Illumination bases for stereo microscopes
ZEISS Illumination bases for stereo microscopes

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter 

TPi-OZX

Glass Plate for Olympus SZ60/40/11 SZ60/40/11 illumination base
・10 year free-repair service for glass breakage ( Applied harden glass )
・Temp. setting range:Ambient – 60℃

Plate:OZX

Tokai-Hit TPi-OZX Themo Plate
Dimensions:W180×D195 mm
Heating area:W162×D152 mm
Glass thickness:1.0 mm
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illuminator base:OLYMPUS SZ60/40/11 illumination stand

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter 

TPi-SZ2

Glass Plate for Olympus SZX7, SZ61 SZ2-ST + SZ2-ILA/ILST
・Temp. setting range:Ambient – 60℃

Plate:SZ2

Tokai-Hit TPi-SZ2 Themo Plate
Dimensions:W278×D175 mm
Heating area:W230×D146 mm
Glass thickness:1.0 mm
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illuminator base:SZ2-ST + SZ2-ILA
EVIDENT Illuminator base:SZ2-ST + SZ2-ILST

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter 

TPi-SZX1

Glass Plate for Olympus MVX10, SZX12/9/7 SZX-ILLK/ILLB2/ILLD2
・Temp. setting range:Ambient – 60℃

Plate:SZX1

Tokai-Hit TPi-SZX1 Themo Plate
Dimensions:W205×D205 mm
Heating area:W170×D170 mm
Glass thickness:1.0 mm
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illuminator base:SZX-ILLK/ILLB2/ILLD2

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter 

TPi-SZX2X

Glass Plate for Olympus SZX16/10 SZX2-ILLB/ILLD/ILLK/ILLT/ILLTQ/ILLTS
・10 year free-repair service for glass breakage ( Applied harden glass )
・With Plate LED Indicator
・Temp. setting range:Ambient – 60℃

Plate:SZX2X

Tokai-Hit TPi-SZX2X Themo Plate
Dimensions:W222×D226 mm
Heating area:W162×D152 mm
Glass thickness:1.0 mm
Controller TPi

Controller:TPi


Dimensions:W85×D135×H30 mm
Weight:170 g
Maximum power consumption:50W

Support Micrscope brand / Stage [Required adapter]

EVIDENT Illuminator base:SZX2-ILLB/ILLK/ILLD
EVIDENT Illuminator base:SZX2-ILLT/ILLTQ/ILLTS

Components

Heating plate 
Controller 
External temperature sensor【SENSOR-TP16】 
Sensor extension wire【EXTD-TP16】 
Software【TEM】
USB cable 
AC adapter